Features:
1. Hybrid Inverter pure sine wave output.
2. Intelligent LCD integration display.
3. Low-frequency toroidal transformer lower loss.
4. Inverter Charger/ Solar Inverter Charger / Built-in PWM or MPPT controller optional.
5. AC charges current 0~30A adjustable, three working modes selectable.
6. Peak power more than 3 times, full-automatic, and perfect protection function.
7. Added fault code query function, easy to monitor the operation in real-time.
8. Supports diesel or gasoline generators, and adapt to any tough electricity situation.
9. Combine industrial and home usage, wall-mounted design, and convenient installation.
Specification:
Model IPS | 10212/24 | 20212/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | ||
Rated Power | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | ||
Peak Power(20ms) | 3KVA | 6KVA | 9KVA | 12KVA | 15KVA | 18KVA | ||
Start Motor | 1HP | 2HP | 3HP | 3HP | 4HP | 4HP | ||
Battery Voltage | 12/24VDC | 12/24/48VDC | 24/48VDC | 24/48VDC | 48VDC | |||
Size(L*W*Hmm) | 500*300*140 | 53*335*150 | ||||||
Packing Size(L*W*Hmm) | 565*395*225 | 605*430*235 | ||||||
N.W.(kg) | 12 | 19 | 20 | 22 | 24 | 26 | ||
G.W.(kg)(Carton Packing) | 13.5 | 19.5 | 21.5 | 24 | 26 | 28 | ||
Installation Method | Wall-Mounted | |||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||||||
AC Input Voltage Range | 85VAC~138VAC(110VAC)95VAC-148VAC(120VAC) / 170VAC~275VAC(220VAC)/180VAC~285VAC(230VAC)/190VAC~295VAC(240VAC) | |||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz)/ | |||||||
Max AC charging current | 0~30A(Depending on the model) | |||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||||
Output | Efficiency(Battery Mode) | ≥85% | ||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2%/220VAC±2%/230VAC±2%/240VAC±2% | |||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | |||||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||||
Efficiency(AC Mode) | >99% | |||||||
Output Voltage(AC Mode_ | 110VAC±10% / 220VAC±10% | |||||||
Output Frequency(AC Mode) | Tracking Automatically | |||||||
Output waveform distortion (Battery Mode) | ≤3%(Linear load) | |||||||
No load loss(Battery Mode) | ≤1% rated power | |||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||||||
No load loss (Energy saving Mode) | ≤10W | |||||||
Battery Type (selectable) | ||||||||
LEAD | Charge Voltage:14V;Float Voltage:13.8V(12V system; 24V system x2; 48V system x4) | |||||||
OP-LE | Charge Voltage:14.2V; Float Voltage:13.8V(12V system; 24V system x2; 48V system x4) | |||||||
LITHIUM | Charge Voltage: 12.6V(NMC battery 3S) (12V system; 24V system x2; 48V system x4) | |||||||
Customize battery | Charge and discharge parameters of different types of batteriescan be customized according to user requirements | |||||||
Protection | Battery undervoltage alarm | 11V; LITHIUM 9.5V(NMC battery 3S)(12V system; 24V system x2; 48V system x4) | ||||||
Battery undervoltage protection | 10.5V; LITHIUM 9V(NMC battery 3S)(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage alarm | Lead acid battery: 15V(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage protection | Lead acid battery: 17V(12V system; 24V system x2; 48V system x4) | |||||||
Battery overvoltage recovery voltage | Lead acid battery: 14.5V(12V system; 24V system x2; 48V system x4) | |||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||
Temperature protection | >90°C(Shut down output) | |||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||||
Inside Solar controller (Optional | Charging Mode | PWM or MPPT | ||||||
charging current | 10A/20A/30A/40A/50A/60A/80A/100A | |||||||
PV Input Voltage Range | PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system) MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) | |||||||
Max PV Input Voltage(At 25℃) | PWM: 50V(12V/24 system), 100V(48V system ); MPPT: 150V | |||||||
PV Array Maximum Power | 12V system: 140W/280W/420W/560W/700W/840W/1120W/1400W; 24V system: 280W/560W/840W/1120W/1400W/1680W/2240W/2800W; 48V system: 560W/1120W/1680W/2240W/2800W/3360W/4480W/5600W | |||||||
Standby loss | ≤3W | |||||||
Maximum conversion efficiency | >95% | |||||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||||
Transfer Time | ≤4ms | |||||||
Display | LCD | |||||||
Thermal method | Cooling fan in intelligent control | |||||||
Communication | RS232/RS485(Optional) | |||||||
Environment | Operating temperature | ≤55dB | ||||||
Storage temperature | -15℃~60℃ | |||||||
Noise | -15℃~60℃ | |||||||
Elevation | 2000m(More than derating) | |||||||
Humidity | 0%~95% ,No condensation |
Output Power : 2000W
Output Type : /
Certification : CE
Origin : Mainland China
Output Current : /
Weight : 18KG
is_customized : Yes
Size : 500*300*140MM
Output Frequency : 50Hz or 60Hz
Package : inner carton & outset carton
AC Input Voltage Range : 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode)
Model Number : IPS-LS-20248
Is Smart Device : Yes
Communication : RS485/GPRS/WIFI(optional)
Wechat/Whatsapp : +86-15876564829
Output Frequency(Battery/PV Mode) : 50Hz±0.5 or 60Hz±0.5
DC Input Voltage Range : 10.5VDC-15VDC
Rated AC input voltage : 220VAC / 230VAC / 240VAC
Email : [email protected]