S Type Differential Switch RCCB Time Delayed RCD ELCB Delay Type Electromagnetic Circuit Breaker

USD 34.39USD 42.99

S Type Differential Switch RCCB Time Delayed RCD ELCB Delay Type Electromagnetic Circuit Breaker

Description

  • Hot Sale

  • Statement:

Both of these are trademarks of our company.

Official website:www.elcb.net

  • generally
     
    ***It is AC-S type delay type RCCB 2P 4P 40A 63A 100mA/300mA***
    S type (delay)
    S-type RCD is a sinusoidal residual current device with time delay. It can be installed upstream of an AC-type RCD to provide selectivity. Delayed RCD cannot be used for additional protection.
    When the circuit has multiple RCCBs, a delay unit can be used "upstream" to allow the RCCB or RCBO downstream of the circuit to trip first and prevent the entire circuit from accidentally tripping.
     
     
     
    TORD1S-63 leakage circuit breaker is suitable for circuits with AC 50/60Hz, 2-pole rated voltage 230V, 4-pole 400V, and rated current up to 100A. When the power grid exceeds the specified value, this product can cut off the fault current in a short time to protect people and equipment. It can also be used for infrequent starting of circuits and motors. This circuit breaker is suitable for various places such as industry, commerce, high-rise building, family and so on.
     
     
    Comply with IEC/EN61008-1.
    The double-sided bus wiring capacity adapts to a wider range of places.
    The maximum connection capacity is 35mm, and the wiring torque is 3.5N*m, which is suitable for a variety of installation equipment.
    Protection level: IP20.
  • Technical Data:

Model Name

TORD1S-63

Model

Electromagnetic type

Residual Current characteristic:

AC

Pole No:

4P

Rated making and breaking capacity

630A

Rated current(A)

63A

Rated voltage

220V 230V AC

Rated frequency

50/60Hz

Rated residual operating current |△(A):

0.1, 0.3

Rated residual non operating current |△ no:

0.5|△ n

Rated conditional short-circuit current inc:

6kA

Rated conditional residual short-circuit current |△c:

6kA

Tripping duration:

time delayed

Residual tripping current range:

0.5||△n~|△n

Electro-mechanical endurance

≥20000 cycles

Connection capacity:

Rigid conductor 25mm⊃2;

Connection terminal

Screw terminalPillar terminal with clamp

Fastening torque

2.0 Nm

Installation

On symmetrical DIN rail 35mmPanel mounting

  • About Us

Specification

Rated voltage : 230V AC

Model Number : TORD1S-63

Type : Earth Leakage

Brand Name : TONGOU

Certification : CE

Rated current : 16A, 40A, 63A

Is Smart Device : NO

Origin : Mainland China

is_customized : Yes

Rated residual operating current : 100 mA, 300 mA

Breaking capacity : 6KA

Electro-mechanical endurance : More than 20000 cycles

Rated making and breaking capacity : 630A

Standard : IEC/EN 61008-1

Residual Current characteristic : AC

Rated frequency : 50/60Hz

Model : Electromagnetic type

+